Features of air cooled industrial water chiller system
1.air cooled industrial water chiller Imported Sanyo/Copeland compressors are used for efficient refrigeration and low noise.
2.air cooled industrial water chiller use Full-function microcomputer control, easy to operate; reasonable internal pipeline layout, effectively reducing energy consumption.
3.air water chiller machine 's Cooling temperature range 5°C-35°C. No cooling tower is required, it is easy to install and move, and is suitable for places where water sources are scarce and no need to install a water tower.
4.air cooled industrial water chiller system The air-cooled type uses a fin condenser to dissipate heat quickly.
5.industrial water chiller has complete safety protection devices such as current overload protection, high and low voltage suppression and electronic time delay.
air cooled industrial water chiller system specifications
MODEL | ZH-3FCS | ZH-5FCS | ZH-8FCS | ZH-10FCS | ZH-15FCS | ZH-20FCS |
Refrigerating capacity | W | 7500 | 12500 | 20000 | 25000 | 37500 | 50000 |
Compressor power | KW | 2.4 | 4.0 | 6.4 | 8 | 12 | 16 |
Cooling water flow | L/min | 21.6 | 36 | 58 | 72 | 108 | 143 |
Chilled water pipe | inch | 1 | 1 | 1 | 1.5 | 2 | 2.5 |
Frozen water pump power | HP | 0.5 | 0.5 | 1 | 1 | 2 | 3 |
Tank capacity | L | 45 | 50 | 100 | 120 | 200 | 300 |
Net weight | Kg | 165 | 195 | 410 | 450 | 670 | 780 |
Outline dimensions | L*W*H(mm) | 1300*700*1300 | 1600*750*1500 | 1900*900*1600 | 2100*1000*1700 |
input power |
| 380V/400V/415V/220V |
Refrigerant |
| R22/410A/R407C/R417A |
Throughput power |
| Capillary tube/expansion valve |
Condenser |
| Fin copper tube air-cooled condenser |
Evaporator |
| Stainless steel water tank copper coil evaporator |
Water cooled industrial chiller usages and features
1.Water cooled chillers need to be used with a cooling water tower
2.Water cooled industrial chiller Imported Sanyo/Copeland compressors are used for efficient refrigeration and low noise.
3.Water cooled industrial chiller use Full-function microcomputer control, easy to operate; reasonable internal pipeline layout, effectively reducing energy consumption.
4.Water cooled industrial chiller Equipped with a precision electronic temperature controller, it can accurately control the water temperature within 3℃ to 35℃.
5.Water cooled industrial chiller has complete safety protection devices such as current overload protection, high and low voltage suppression and electronic time delay.
Water cooled industrial chiller Specifications
Model | ZH-3WC | ZH-5WC | ZH-8WC | ZH-10WC | ZH-12WC |
Refrigerating capacity | W | 9000 | 15000 | 24000 | 30000 | 36000 |
Compressor power | KW | 2.5 | 4.5 | 6.4 | 8.2 | 9.6 |
Cooling water flow | L/min | 34 | 56 | 88 | 114 | 146 |
Chilled water pipe | INCH | 1 | 1 | 1.5 | 1.5 | 1.5 |
Cooled water flow | L/min | 90(25L) | 90(43L) | 200(69L) | 200(86L) | 200(104L) |
Chilled water pipe |
| 4组4分 | 4组4分 | 1 | 1.5 | 1.5 |
Frozen water pump power | HP | 0.5 | 0.5 | 1 | 1 | 2 |
Tank capacity | L | 45 | 50 | 120 | 120 | 160 |
Net weight | Kg | 100 | 140 | 280 | 350 | 400 |
Outline dimensions | LxWxH(mm) | 850*520*900 | 850*520*900 | 1300*700*1200 | 1300*700*1200 | 1300*700*1200 |
Refrigerant | R22/410A/R407C/R417A |
input power | 380V/400V/415V/220V etc. |
Screw industrial water chiller features
1.Screw industrial water chiller Imported semi-hermetic screw and semi-hermetic reciprocating compressors. Good performance and low noise.
2.Screw industrial water chiller use the evaporator copper tube adopts internal and external thread reinforced tube, which has good cooling effect.
3.Screw industrial water chiller the condenser uses imported copper tubes, which are processed into trapezoidal low-assist tubes to enhance heat transfer capabilities. The smooth surface of the copper pipe reduces water pressure and is easy to clean and maintain.
4.Screw industrial water chiller use computer control system: Highly intelligent PLC and PC_level computer control system, which can be used for remote monitoring and control. The operation is simple and the host computer is connected to the power supply. Low failure rate, high safety factor and simple installation.
Screw industrial water chiller specifications
model | ZHSC-40 | ZHSW-50 | ZHSC-60 | ZHSC-70 | ZHSC-80 | ZHSC-100 | ZHSC-120 |
Refrigerating capacity | KW | 119 | 149 | 179 | 209 | 239 | 297 | 3602 |
Compressor | KW | 30 | 37 | 45 | 52 | 60 | 75 | 90 |
Cooling water flow | L/min | 450 | 600 | 700 | 900 | 950 | 1200 | 1400 |
Chilled water pipe | mm | Ф100 | Ф100 | Ф100 | Ф125 | Ф125 | Ф125 | Ф125 |
Chilled water flow | L/min | 341 | 427 | 513 | 599 | 685 | 851 | 1051 |
Chilled water pipe | mm | Ф100 | Ф100 | Ф100 | Ф135 | Ф135 | Ф135 | Ф135 |
Refrigerating circuit |
| 1 | 1 | 1 | 2 | 2 | 2 | 2 |
Outline dimensions | LxWxH(mm) | 2200*800*1550 | 2500*850*1600 | 2650*900*1750 | 2800*900*1800 | 3000*950*1800 | 3000*980*1820 | 3000*980*1920 |
Net weight | KG | 850 | 950 | 1100 | 1500 | 1900 | 2500 | 2600 |
input power | 3P 380V/400V/415V/220V |
Refrigerant | R22/R410A/R407C/R134A |
Condenser | shell and tube condenser |
Evaporator | Shell and tube evaporator |
throttle power | Expansion valve |
Water cooling tower usages
Water cooling tower is a device used to lowering water temperature and it is usually used in industrial production and air conditioning systems. Its function is to draw hot water from the production equipment or cooling system and spray it through the filling material and spray system in the cooling tower, so that the water comes into contact with the air and gradually cools down,and then returned to the production equipment or cooling system to continue recycling.
There are normal temperature water cooling towers and high temperature water cooling towers, round cold water towers and square cold water towers. Customers can choose the appropriate model according to actual needs.
Specifications
Model | Flow rate m³/h | Dimensions (mm) | MOLOR (kw) | FAN (mm) | Air flow (cmm) | pressue (kpa) | Weight(kg) |
φ | H | standard | low noise |
DRY | WET | DRY | WET |
ZHT-50L | 39.2 | 1800 | 1835 | 1.5 | 890 | 230 | 17 | 190 | 975 | 210 | 1050 |
ZHT-60L | 46.0 | 2145 | 1955 | 1.5 | 1150 | 420 | 17 | 240 | 1250 | 160 | 1200 |
ZHT-80L | 62.6 | 2145 | 2035 | 1.5 | 1150 | 450 | 18 | 260 | 1280 | 290 | 1410 |
ZHT-100L | 78.1 | 2900 | 2370 | 2.2 | 1410 | 700 | 21 | 500 | 1690 | 550 | 1650 |
ZHT-150L | 117 | 2900 | 2555 | 2.2 | 1410 | 950 | 23 | 580 | 1680 | 600 | 1750 |
ZHT-200L | 156.2 | 3310 | 3185 | 4 | 1750 | 1250 | 30 | 980 | 1980 | 920 | 2100 |
ZHT-250L | 195.1 | 4120 | 3690 | 5.5 | 2100 | 1750 | 33 | 1080 | 2800 | 1200 | 2950 |
ZHT-300L | 231 | 4730 | 3690 | 7.5 | 2400 | 2000 | 34 | 1760 | 3030 | 1820 | 4050 |
ZHT-400L | 312.1 | 5600 | 3840 | 11 | 2745 | 2400 | 36 | 2940 | 5740 | 2920 | 5800 |
ZHT-500L | 392.4 | 5600 | 3840 | 15 | 2745 | 2500 | 36 | 2900 | 5800 | 3010 | 5950 |
ZHT-600L | 469 | 5600 | 4470 | 15 | 3400 | 3750 | 42 | 3950 | 9350 | 4050 | 9450 |
ZHT-700L | 547.2 | 5600 | 4470 | 18.5 | 3400 | 3750 | 42 | 4050 | 9450 | 4150 | 9500 |
ZHT-800L | 626.4 | 7600 | 4720 | 22 | 3700 | 5000 | 45 | 4700 | 11900 | 4900 | 12100 |
ZHT-1000L | 781.2 | 7600 | 4720 | 22 | 3700 | 5400 | 45 | 4900 | 12100 | 5000 | 12300 |